Disinfection process validation with bacteria
Disinfection process validation by using DioFog-Controller bioindicators with test bacteria
DioFog Controller “closed germ-carriers”: Bioindicators with official test bacteria
Validations using conventional agar contact plates (classical way) may be unsafe due to application mistakes. By using DioFog-Controller, this problem may easily be a thing of the past because:
The DioFog-Controller procedure uses so called “closed germ-carriers”, whose testing germs (thermo-resistant reference-germs of the ATTC 6057) are coated by a thermally, mechanically and chemically stable but still flexible membrane and a run-off of testing germs or a re-contamination of the germ-carrier is surely prevented.
The DioFog-Controller KT-4 (3004 S) is developed to verify room disinfection procedures according to European norms, international standards and the German RKI (Robert Koch Institute) guidelines.
The DioFog-Controllers are bioindicators for the probably easiest and safest validation of hydrogen peroxide based room, air and surface disinfections through aerosolized Hydrogen Peroxide (aHP).
Advantages of disinfection process validation with DioFog-Controllers

European certified disinfection validation

Easy, quick, reliable and safe disinfection validation without any risk of recontamination

Clinically proven and scientfically tested validation method

Disinfection validation according to International standards and European norms
DioFog-Controller product features
Short overview about the basic data of DioFog Controller bioindicators:
Material | The testing germs of DioFog-Controller are coated by a mechanically, chemically and thermally stable membrane |
Dimensions | 156 x 41 x 1 mm (H x W x L) |
Weight | about 1.5 g |
Batch system | Yes, every bioindicator has a unique ID number |
Number of controllers for room disinfection | 1 DioFog-Controller for every 15 m3, but for conclusive validation test, use at least 3 pieces + 1 transport control |
Expiration date | 6 weeks from date of delivery |
Specification | KT-4 (3004 S) |
Standard | DIN EN ISO 15883 |
Purpose | Disinfection validation of hydrogen peroxide room disinfection / aerosolized Hydrogen Peroxide (aHP) |
Log reduction | 3-7 log (99,9% to 99,99999%) |
Test germs | Thermo-resistant reference-germs of the ATTC 6057: Enterococcus faecium or Staphylococcus aureus |
Seller | DIOP GmbH & Co. KG / Germany |