Disinfection process validation with bacteria

Disinfection process validation by using DioFog-Controller bioindicators with test bacteria

Disinfection process validation


DioFog Controller “closed germ-carriers”: Bioindicators with official test bacteria

Validations using conventional agar contact plates (classical way) may be unsafe due to application mistakes. By using DioFog-Controller, this problem may easily be a thing of the past because:

The DioFog-Controller procedure uses so called “closed germ-carriers”, whose testing germs (thermo-resistant reference-germs of the ATTC 6057) are coated by a thermally, mechanically and chemically stable but still flexible membrane and a run-off of testing germs or a re-contamination of the germ-carrier is surely prevented.

The DioFog-Controller KT-4 (3004 S) is developed to verify room disinfection procedures according to European norms, international standards and the German RKI (Robert Koch Institute) guidelines.

The DioFog-Controllers are bioindicators for the probably easiest and safest validation of hydrogen peroxide based room, air and surface disinfections through aerosolized Hydrogen Peroxide (aHP).

Advantages of disinfection process validation with DioFog-Controllers

Certified disinfection validation

European certified disinfection validation

Safe validation

Easy, quick, reliable and safe disinfection validation without any risk of recontamination

Reliable validation

Clinically proven and scientfically tested validation method


Disinfection validation according to International standards and European norms

DioFog-Controller product features

Short overview about the basic data of DioFog Controller bioindicators:

Material The testing germs of DioFog-Controller are coated by a mechanically, chemically and thermally stable membrane
Dimensions 156 x 41 x 1 mm (H x W x L)
Weight  about 1.5 g
Batch system  Yes, every bioindicator has a unique ID number
Number of controllers for room disinfection 1 DioFog-Controller for every 15 m3, but for conclusive validation test, use at least 3 pieces + 1 transport control
Expiration date 6 weeks from date of delivery
Specification KT-4 (3004 S)
Standard DIN EN ISO 15883
Purpose Disinfection validation of hydrogen peroxide room disinfection / aerosolized Hydrogen Peroxide (aHP)
Log reduction 3-7 log (99,9% to 99,99999%)
Test germs Thermo-resistant reference-germs of the ATTC 6057: Enterococcus faecium or Staphylococcus aureus
Seller DIOP GmbH & Co. KG / Germany

DioFog-Controller impressions

H2O2 disinfection validation

Disinfection validation bioindicators